Method 201A: Determination of PM10 emissions (constant
sampling rate procedure)
Draft Method 201B: Determination of PM10 and PM2.5 emissions (constant
sampling rate procedure)
PM10-SS
Cyclone and Nozzle Set
The ESC PM10 Cyclone and Nozzle Set
is manufactured to the interior dimensional specifications defined by the USEPA
in Method 201A for in-stack measurement of particulate matter 10 microns and
less. Sets are available in stainless steel and Teflon-coated stainless steel
and include the cyclone body, 11 nozzles and a 47mm in-line filter holder in a
foam-lined case. The filter holder outlet mounts directly to a standard Method 5
probe assembly. The PPS12-Y-PM10 Modular Type S Pitot Tip is required to extend
the pressure planes even with the cyclone inlet nozzle.
PM2.5-SS
Cyclone and Nozzle Set
The ESC PM2.5 Cyclone and Nozzle Set
is manufactured to the dimensional specifications defined by the USEPA and
Southern Research Institute originally published in the Application Guide for
Measurement of PM2.5 [and less] at Stationary Sources. The Set is available in
stainless steel and Teflon-coated stainless steel and includes the cyclone body,
6 nozzles and a 47mm in-line filter holder in a foam-lined case.
PM10-2.5-SS
Combination PM10 and PM2.5 Cyclone and Nozzle Set

The draft
method for determination of PM10 and PM2.5 specifies the procedure for
simultaneous in-stack segregation of particulate matter greater than PM10, equal
to or less than PM10 but greater than PM2.5, and equal to or less than PM2.5.
The particulate matter is recovered from three clearly defined zones within the
dual cyclone assembly. Each PM10-25-SS combination set includes a PM10 cyclone,
11 PM10 nozzles, a 47mm filter assembly, a PM2.5 cyclone, the cascade adapter
linking device and full assembly support cradle.
VOST: Determination of volatile organic
compounds in gaseous emissions from stationary sources (SW-846 Methods 0030 and
0031)
V-S1
Single VOST and V-S2 Dual VOST Samplers
The ESC Single and Dual VOST
(Volatile Organic Sampling Train) Samplers are used in conjunction with the
UNI-VOS-110 Low Flow Control Console to perform SW-846 Methods 0030 and 0031.
Volatile organic compounds in the sample stream are passed through a Pyrex coil
condenser followed by cartridges packed with Tenax, Tenax/charcoal or Anasorb
adsorbent material. The cartridges are thermally desorbed prior to analysis of
the volatile organics by gas chromatography/mass spectroscopy.
The V-S1 Single VOST Sampling System
uses a single glassware set. The V-S2 Dual VOST Sampling System holds two
glassware sets in a single caddy with a 4-way valve at the outlet end to allow
continuous sampling. After a sample run the valve can be switched to the other
glassware set for sampling while sorbent cartridges in the first set are changed
and leak check is performed. Two separate pumps in the UNI-VOS-110 Console with
dual pump option allow simultaneous sampling and leak checking.
UNI-VOS-110
Low Flow Control Console
The
UNI-VOS-110 is the ideal Metering Control Console for accurate volume
measurements in low flow gas sampling methods requiring sample rates from 0.5 to
2 liters per minute. The flow rate adjustments, gauges and temperature readouts
on the console and the 0.01 Liter resolution of the dry gas meter allow the
tester to maintain a constant and accurate flow rate while monitoring gas meter
pressure and temperature and five remote temperatures. Two digital temperature
controllers are provided for maintaining probe and filter heat.
Alternatively the C-5000 Isokinetic Control Console can be used with an
appropriately sized CO-FA style Orifice Flow Adapter.
Method 0061: Determination of hexavalent chromium from
stationary sources
HC-S1
Hexavalent Chromium Isokinetic Sampler

The
ESC HC-S1 Hexavalent Chromium Isokinetic Sampler is designed to aspirate the
potassium hydroxide impinger solution behind the nozzle in order to impede
molecular changes to the hexavalent chromium once sample is drawn from the
source. The Sampler includes a heated, Teflon lined, isokinetic probe assembly
with recirculating nozzle union, PFA Teflon Impinger Set, peristaltic
recirculating pump, insulated cold box with probe support adapter and pump
shelf, umbilical adapter with power distribution box and a PFA Teflon filter
column. The filter column is used for filtration of hexavalent chromium samples
prior to analysis.
The
HC-S2 High Temperature Hexavalent Chromium Isokinetic Sampler

The
HC-S2 High Temperature Hexavalent Chromium Isokinetic sampler is recommended for
use on sources with temperatures above 300°F. This sampler replaces some Teflon
components with either Pyrex or Quartz alternatives in order to eliminate
exposure of Teflon components from the probe assembly and potassium hydroxide
recirculation lines to the elevated stack temperature.
NCASI Method 8A: Determination of sulfuric
acid vapor or mist and sulfur dioxide emissions from kraft recovery furnaces
The ESC controlled condensate system
utilizes a high temperature oven to house a thimble filter holder followed by a
heated coil condenser that is carefully temperature controlled within very
narrow tolerances to achieve separation of sulfuric acid vapor or mist
(including sulfur trioxide) and sulfur dioxide. Both fractions are measured
separately by the barium-thorin titration method. The system includes a heated
quartz lined probe and high temperature oven each capable of maintaining 550°F,
quartz thimble filter holder, Pyrex coil condenser with thermocouple port on
recirculation jacket, Pyrex condenser exit adapter with thermocouple port and
heated water bath with recirculating pump. The oven is equipped with hanging
brackets, a probe support bracket on the inlet end and a condenser cradle on the
outlet end so that all glassware is protected and securely supported. A flexible
transfer line is used to carry the separated sample to a chilled Pyrex
3-impinger set.
|