Method 23: Determination of polychlorinated dibenzo-p-dioxins
and poly-chlorinated dibenzofurans emissions from
stationary sources
This
system uses a standard Method 5 system augmented by our riserless Method 23
extension glassware. This additional glassware consists of the "S"
connector from the filter, horizontal Pyrex coil condenser, XAD sorbent trap and
moisture knockout impinger. We also carry the vertical Pyrex coil condenser for
use with a riser box that will accommodate the extra height required by the
condenser and XAD trap mounted on top of the first impinger. Our 8-impinger
coldbox is recommended to accommodate the required M23-RC Coolant Recirculating
Pump,
the standard Method 5 impinger set and the Method 23 extension glassware.
This Method 23 Sampling System can also be used for Method 0010, Determination
of Semi-volatile Organic Compounds.

Method 23 Extension Glassware (Extension Sets
to Augment Standard Method 5 Glassware Sets Are Available):
| GP-150 |
'S' Connector |
| GP-151 |
Horizontal Coil Condenser, Ball
Joint with O-ring |
| GP-151V |
Vertical Coil Condenser, Ball
Joint with O-ring |
| GP-152 |
XAD Resin Trap, Ball Joint with
O-ring |
| GP-153 |
Short Knockout Impinger, Ball
Joint with O-ring, Accommodates XAD Trap |
| GP-154 |
Ball Stopper (To Seal XAD Trap
Socket End) |
| GP-155 |
Stocket Stopper (To Seal XAD
Trap Ball End) |
M23-RC
Coolant Recirculating Pump, 115V/60Hz
Methods
23 & 29 Teflon Cleanup and Recovery Tools
| PRB-T8 |
All Teflon 1/2" Probe Brush |
| PRB-EXT-4 |
1/4" Teflon Probe Brush
Extension with 3/8" Coupler, per foot |
| M23-CK8 |
Teflon Coated Stainless Steel
Spatula |
| M23-CK9 |
Teflon Coated Stainless Steel
Forceps |
| M23-CK11 |
500 ml Teflon Wash Bottle |
| M23-CK1224 |
12" x 24" x 0.03"
Virgin PTFE Sheet |
Method 26: Determination of hydrogen chloride emissions from
stationary sources
The
ESC M26-S1-H Method 26 Sampler includes a 6-impinger glassware set preceded by a
heated 3-way Pyrex valve with Teflon plunger and Teflon filter holder attached
at the outlet of the heated probe assembly. The M26-VFH valve and filter heater
is a modular clamshell oven that mounts on our Method 6 and Method 26 midget
sample caddy directly behind the probe support. The particulate matter and
halide salts collected on the filter are usually discarded and the impinger
solutions are analyzed by ion chromatography.
The
UNI-VOS-110 is the ideal Metering Control Console for accurate volume
measurements in low flow gas sampling methods requiring sample rates from 0.5 to
2 liters per minute. The flow rate adjustments, gauges and temperature readouts
on the console and the 0.01 Liter resolution of the dry gas meter allow the
tester to maintain a constant and accurate flow rate while monitoring gas meter
pressure and temperature and five remote temperatures. Two digital temperature
controllers are provided for maintaining probe and filter heat.
GSM-26B Method 26 Midget
Glassware Set:
Our standard GSM-26B Midget
Glassware & Filter Holder Set is precision ground ball and socket joint with
O-ring for leak-free performance. The PFA Teflon Filter Holder includes a PFA
Teflon Nut with integrated ferrule for leak free attachment to probe liner at
the inlet and Pyrex 3-way valve at the outlet.
| 1 |
GFT-2-6 |
PFA Teflon Filter Holder,
3/8" Tube Fittings |
| 1 |
GP-606 |
3-Way Pyrex Valve, Teflon
Plunger |
| 6 |
GP-607 |
Midget Impinger, Modified (without
Orifice) |
| 5 |
GP-609 |
Midget U-Tube Connector |
| 12 |
GP-611 |
#12 Ball Joint Clamp, Stainless
Steel |

Method 29: Determination of metals emissions from
stationary sources
The Method 29 sampling system is an
augmented Method 5 sampling train that includes the addition of up to 3
impingers to the standard Method 5 glassware set. The expanded impinger set is
necessary to hold solutions that are specific for up to 17 different metals and
are analyzed by various spectroscopy methods. Quartz fiber filters without
organic binder are required to avoid contamination and artifacts.

Methods