Method 3: Gas Analysis for CO2, O2, Excess Air and Dry Molecular Weight

This method provides for gas captured froma source to be delivered to a Tedlar bag at a constant flow rate. The bag contents is then analyzed for the gaseous parameters of interest. If a leak-free pump is placed in-line before the Tedlar bag, a moisture removal system must precede the pump for protection.

Intrinsically Safe Bag Sampling System

ESC Integrated Bag Sampling Systems include a bag vessel (10, 20, 30, 50 or 100 Liter internal volumes), a pump module with rotameter, valve, vacuum gauge and a quick connect on the vacuum and pressure side of the pump. The bag vessel is intrinsically safe, capable of maintaining 29" Hg vacuum, and can be used to sample in volatile areas where the use of electricity is prohibited.

 

 

Tedlar Bags

ESC makes Tedlar bags in a variety of sizes and with a variety of valve configurations. Valves include a nickle plated hose barb valve, a septum fitting, a polypropylene valve and septum fitting, and a Teflon nut used to receive a variety of stainless steel quick connects or unions.

 

GCU-2 Coil Condenser System


Coil Condenser systems include either a coil condenser in an ice bath, such as our GCU series of moisture knockout systems, or a series of knockout impingers that comprise the condensing system as used in Method 4. Coil condensers are available with FEP Teflon or stainless steel coils and include a PFA Teflon catch vessel and a peristaltic pump to evacuate the collected condensate. 

 

 

 

TEDLAR BAG LUNG SAMPLERS
BSS-10 10 Liter Bag Sampling System, Transparent, 120V Pump Assembly
BSS-20 20 Liter Bag Sampling System, Transparent, 120V Pump Assembly
BSS-30 30 Liter Bag Sampling System, Transparent, 120V Pump Assembly
BSS-50 50 Liter Bag Sampling System, Polycarbonate Vessel, 120V Pump Assembly
BSS-100 100 Liter Bag Sampling System, Polycarbonate Vessel, 120V Pump Assembly
BV10 10 Liter Transparent Acrylic Bag Vessel, 3-Way SS Valve, 1/4" QC
BV20 20 Liter Transparent Acrylic Bag Vessel, 3-Way SS Valve, 1/4" QC
BV30 30 Liter Transparent Acrylic Bag Vessel, 3-Way SS Valve, 1/4" QC
BV50 50 Liter Polycarbonate Bag Vessel w/ Viewing Window, 3-Way SS Valve, 1/4" QC
BV100 100 Liter Polycarbonate Bag Vessel w/ Viewing Window, 3-Way SS Valve, 1/4" QC
PS-33 Pump Assembly, 9 LPM, 25"Hg, 120V, Valved Rotameter, Vacuum Gauge
PS-33-V Pump Assembly, 9 LPM, 25"Hg, 220V, Valved Rotameter, Vacuum Gauge
     220VAC Systems are available. Please contact ESC for quote
     TEDLAR BAGS: See Tedlar Bag Section At End Of Catalog
GCU-2 Universal Gas Conditioning Assembly with Teflon Coil
C-CC-T 3/8" Teflon Coil Condenser, M5-CB6-C Insulated Cold Box, Modified with Bored-Thru Coil Condenser Outlet, M5-CB-PA Probe Support Adapter Panel for Cold Box, M5-CB6-BPS Cold Box Bottom Pump Peristaltic PumpShelf, HC-PPS-2 Peristaltic Pump, TC-504-6 PFA Teflon Column Segment w/ 3/8" Side Inlet Port, TC-501-6 PFA Column Top w/ 3/8" Outlet Port, TC-501-4 PFA Column Bottom Cap w/ 1/4" Outlet Port, UC-25C 25' CEM Umbilical With Connector Box
GCU-2S Universal Gas Conditioning Assembly with SS Coil
3/8" SS Condenser & Condensate Evacuation Vessel
M3-OGA ORSAT Analyzer, Glassware, Cabinet and Hardware
(2) M3-OGA-1 Absorption Pipet, Contact, (1) M3-OGA-2 Absorption Pipet, Auto Bubbler, (1) M3-OGA-3 Buret, 100ml, 3-Way Valve, (1) M3-OGA-4 Buret Water Jacket & Ends, (1) M3-OGA-5 Manifold, 3-Port, 3-Way Valves, (1) M3-OGA-6 Reagent Bottle, 125ml, (1) M3-OGA-7 Orsat Case, Doors, Hardware, Accessories, (1) M3-OGA-8 Orsat Gas Expansion Bag, Latex

 

Method 4: Determination of moisture content in stack gases

The Method 4 sampling train is an abbreviated Method 5 system that provides all of the equipment necessary to determine moisture content with the addition of our M5-CB-PA Probe Support Panel and M5-JB-1 Power Distribution Box that mount directly to the standard cold box that holds the condenser set of impingers.

 

 

M4-S1 METHOD 4 SAMPLING SYSTEM
M5-CB6 6-Impinger Insulated Cold Box, M5-CB-PA Probe Support Panel, GS-M4 Method 4 Glassware Set, M5-UA Umbilical Adapter w/ Check Valve, UC-25 25' Umbilical Cable, 3' Heated Probe with 1" Sheath and 5/8" SS Liner
GS-M4 Method 4 Glassware Set
(1) GP-103 Double "L" Connector, (1) GP-104 Greenburg-Smith Impinger, (3) GP-105 Modified Impinger, (3) GP-106 U-Tube Connector, (9) GP-109 #28 Stainless Steel Ball Joint Clamp
GS-CCS Stainless Steel Coil Condensor Assembly
#28 SS Socket Inlet, 3/8" SS Coil, KO Impinger, SS U-Tube, SS Impinger Assembly
C-CCA-6SS 3/8" SS Coil Condenser
SSP-104W-66 Stainless Steel Impinger, Welded, 3/8" Top Ports (2)
SSP -104W-664 Stainless Steel Impinger, Welded, 3/8" Top Ports (2), 1/4" Bottom Outlet Port
SSP -104-66 Stainless Steel Impinger, Screwtop, 3/8" Top Ports (2)
SSP -104-664 Stainless Steel Impinger, Screwtop, 3/8" Top Ports (2), 1/4" Bottom Outlet Port
SSP -104-66KO Stainless Steel Short Knockout Impinger, Screwtop, 3/8" Top Ports (2)
 