Method 6: Determination of SO2 emissions from
stationary sources
The
ESC Method 6 Sampling Train is an efficient low flow, non-isokinetic system for
extracting a gas sample from the stack and separating the sulfuric acid mist,
including sulfur trioxide, from the sulfur dioxide fraction that is to be
measured using barium-thorin titration. This train is outfitted with a
miniature, pyrex lined, heated probe assembly, a midget sample caddy with
insulated glassware tray, a midget glassware set, the impinger outlet adapter
with thermocouple and the UC-25U umbilical cable with connector box.
UNI-VOS-110
Low Flow Control Console
The
UNI-VOS-110 is the ideal Metering Control Console for accurate volume
measurements in low flow gas sampling methods requiring sample rates from 0.5 to
2 liters per minute. The flow rate adjustments, gauges and temperature readouts
on the console and the 0.01 Liter resolution of the dry gas meter allow the
tester to maintain a constant and accurate flow rate while monitoring gas meter
pressure and temperature and five remote temperatures. Two digital temperature
controllers are provided for maintaining probe and filter heat. Alternatively the C-5000 Isokinetic Control Console can be used with an
appropriately sized CO-FA style Orifice Flow Adapter.
GSM-6B
Method 6 Midget Glassware Set:
Our standard GSM-6B Midget Glassware Set is
precision ground ball and socket joint with O-ring for leak-free performance.
The stem-to-bottle taper joint is also a precision ground joint with O-ring
seal.

(1) GP-606 3Way Pyrex Valve
(4) GP-607 Midget Impinger
(1) GP-608 Orifice Impinger
(4) GP-609 Midget U-Tube
(12) GP-611 SS Pinch Clamp
Method 7: Determination of nitrogen oxide emissions from
stationary sources

Methods 7, 7A and 7B are variations of the
non-isokinetic nitrogen oxide determination method that provide for three
different analytical procedures of a grab sample that is collected in an
evacuated 2 liter flask containing a dilute solution of sulfuric acid and
hydrogen peroxide. Our M7-S1 Method 7 Sampling system consists of a heated,
Pyrex lined probe assembly, a sample caddy, multiple evacuation flasks, a 3-way
Pyrex valve, a hand purge pump, an evacuation pump, a 3-way pump selection
valve, and digital manometer pressure sensor.
Methods 7C and 7D provide for
nitrogen oxide determination by drawing a low flow sample through a heated,
Pyrex lined probe assembly and an arrangement of three standard orifice
impingers containing an alkaline-potassium- permanganate solution and a dryer
impinger. The UNI-VOS-110 is the ideal control console to complete the system.
Method 8: Determination of sulfuric acid mist and sulfur
dioxide emissions from stationary sources
Method
8 utilizes an isokinetic sampling system where the filter is unheated and placed
between the first and second impinger of a glassware set that alternates orifice
and straight stem impingers. We provide three accessories for the performance of
Method 8 to replace the standard filter and heated filter box in the Method 5
sampling train.
  
|